Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
J. bras. pneumol ; 45(4): e20180264, 2019. tab, graf
Article in English | LILACS | ID: biblio-1019983

ABSTRACT

ABSTRACT Objective: To determine whether airway narrowing during obstructive events occurs predominantly at the retropalatal level and results from dynamic changes in the lateral pharyngeal walls and in tongue position. Methods: We evaluated 11 patients with severe obstructive sleep apnea (OSA) and 7 healthy controls without OSA during wakefulness and during natural sleep (documented by full polysomnography). Using fast multidetector CT, we obtained images of the upper airway in the waking and sleep states. Results: Upper airway narrowing during sleep was significantly greater at the retropalatal level than at the retroglossal level in the OSA group (p < 0.001) and in the control group (p < 0.05). The retropalatal airway volume was smaller in the OSA group than in the control group during wakefulness (p < 0.05) and decreased significantly from wakefulness to sleep only among the OSA group subjects. Retropalatal pharyngeal narrowing was attributed to reductions in the anteroposterior diameter (p = 0.001) and lateral diameter (p = 0.006), which correlated with an increase in lateral pharyngeal wall volume (p = 0.001) and posterior displacement of the tongue (p = 0.001), respectively. Retroglossal pharyngeal narrowing during sleep did not occur in the OSA group subjects. Conclusions: In patients with OSA, upper airway narrowing during sleep occurs predominantly at the retropalatal level, affecting the anteroposterior and lateral dimensions, being associated with lateral pharyngeal wall enlargement and posterior tongue displacement.


Resumo Objetivo: Determinar se o estreitamento das vias aéreas durante eventos obstrutivos ocorre predominantemente na região retropalatal e resulta de alterações dinâmicas nas paredes laterais da faringe e na posição da língua. Métodos: Avaliamos 11 pacientes com apneia obstrutiva do sono (AOS) grave (grupo AOS) e 7 indivíduos saudáveis sem AOS (grupo controle) durante a vigília e o sono natural (documentado por meio de polissonografia completa). Por meio de TC multidetectores rápida, obtivemos imagens das vias aéreas superiores no estado de vigília e de sono. Resultados: O estreitamento das vias aéreas superiores durante o sono foi significativamente maior na região retropalatal do que na região retrolingual no grupo AOS (p < 0,001) e no grupo controle (p < 0,05). O volume da via aérea retropalatal foi menor no grupo AOS do que no grupo controle durante a vigília (p < 0,05) e diminuiu significativamente da vigília ao sono apenas no grupo AOS. O estreitamento retropalatal da faringe foi atribuído à redução do diâmetro anteroposterior (p = 0,001) e lateral (p = 0,006), que se correlacionou com o aumento do volume das paredes laterais da faringe (p = 0,001) e o deslocamento posterior da língua (p = 0,001). Não ocorreu estreitamento retrolingual da faringe durante o sono no grupo AOS. Conclusões: Em pacientes com AOS, o estreitamento das vias aéreas superiores durante o sono ocorre predominantemente na região retropalatal e afeta as dimensões anteroposterior e lateral, além de estar relacionado com aumento das paredes laterais da faringe e deslocamento posterior da língua.


Subject(s)
Humans , Male , Adult , Middle Aged , Aged , Tongue/diagnostic imaging , Pharyngeal Diseases/diagnostic imaging , Sleep Apnea, Obstructive/diagnostic imaging , Multidetector Computed Tomography/methods , Palate/physiopathology , Palate/pathology , Palate/diagnostic imaging , Pharynx/physiopathology , Pharynx/pathology , Pharynx/diagnostic imaging , Reference Values , Respiratory Tract Diseases/physiopathology , Respiratory Tract Diseases/pathology , Respiratory Tract Diseases/diagnostic imaging , Tongue/physiopathology , Tongue/pathology , Wakefulness/physiology , Pharyngeal Diseases/physiopathology , Pharyngeal Diseases/pathology , Case-Control Studies , Polysomnography , Sleep Apnea, Obstructive/physiopathology , Sleep Apnea, Obstructive/pathology
2.
São Paulo; s.n; 2011. [73] p. ilus, tab, graf.
Thesis in Portuguese | LILACS | ID: lil-609401

ABSTRACT

Introdução: O acúmulo de líquido na cavidade pleural afeta a dinâmica do sistema respiratório repercutindo no seu comportamento funcional. Contudo, seus efeitos sobre o sono permanecem indefinidos. Objetivos: Determinar a qualidade do sono e o grau de hipoxemia durante a vigília e sono antes e após a toracocentese de alívio em portadores de derrame pleural. Casuística e Métodos: Dentre os pacientes atendidos no grupo de doenças pleurais do HC-FMUSP foram selecionados, de forma consecutiva pacientes clinicamente estáveis com derrame pleural volumoso unilateral no estudo radiológico do tórax. Todos responderam questionários de sono incluindo Epworth Sleepiness Scale, Pittsburgh Sleep Quality Index e Escala de Dispnéia Modificada de Borg. Os pacientes foram submetidos à polissonografia completa e questionários antes e após a punção esvaziadora. Resultados: Foram estudados 19 pacientes, com idade média de 55 ± 18 anos, sendo 11 do sexo masculino. Na presença de líquido pleural, a qualidade objetiva do sono basal não foi satisfatória (PSQI: 9,1 ± 3,5). Após a retirada de 1.624 ± 796 mL houve diminuição significante do índice de dispnéia (Escala Modificada de Borg: 2,3 ± 2,1 vs 0,8 ± 0,9; p < 0,001). As polissonografias pré e pós-toracocentese não demonstraram mudanças no índice apnéia-hipopnéia e no tempo de sono com saturação periférica de oxigênio inferior a 90 %. Houve, após a toracocentese, melhora significativa (p < 0,05) na eficiência do sono e aumento significativo da latência do sono, diminuição da latência do sono e do sono REM e no percentual de sono de estágio 1. Observou-se tendência no aumento do tempo total de sono, no tempo acordado após o início do sono e no percentual de sono REM. A melhora da qualidade do sono não se correlacionou com o volume de líquido pleural retirado, com mudanças no grau de dispnéia ou da SpO2 durante o sono. Conclusões: Pacientes com derrames pleurais volumosos têm qualidade de sono subjetiva e objetivamente...


Introduction: Large pleural effusion affects pulmonary physiology. However, the impact of pleural effusion on sleep remains unknown. Objectives: To determine the sleep quality and hypoxemia levels during awakeness and sleep before and after therapeutic thoracentesis in patients with pleural effusion. Methods: Among patients of Pleural Diseases Clinic at the Hospital das Clinicas da FMUSP, were recruited clinically stable consecutive patients with large unilateral pleural effusion documented by chest radiograph. All these patients were evaluated by Pittsburgh Sleep Quality Index (PSQI) questionnaire, Epworth Sleepiness Scale (ESS) before polysomnography. Dyspnea Borg scale and full polysomnography were also performed before and after thoracentesis. Results: We studied 19 patients (11 males), age 55 ± 18 years and body mass index 26 ± 5 kg/m2. The baseline quality of sleep was poor (PSQI = 9.1 ± 3.5). The amount of pleural fluid removed was 1624 ± 796 mL and resulted in a significant decrease in dyspnea according to Borg scale (2.3 ± 2.1 vs 0.8 ± 0.9, p < 0.001). The polysomnography before and after thoracentesis showed no significant changes in apnea hypopnea index and sleep time with oxygen saturation (SpO2) < 90%. Significant improvements (p < 0.05) occurred in sleep efficiency, increase in sleep onset, decrease in rapid eye movement (REM) latency from sleep onset and percentage of stage 1 sleep. There was a trend improvement in total sleep time, wake time during sleep period and percentage of REM sleep. However, the improvement in sleep quality was not associated with volume of pleural fluid withdrawn, changes in dyspnea or SpO2 during sleep. Conclusions: Patients with large pleural effusions have poor subjective and objective sleep quality that improves after thoracentesis. Finally, there was no impact of thoracentesis on hypoxemia levels during sleep and awakeness and no relationship was observed between the amount of fluid withdrawn and dyspnea...


Subject(s)
Humans , Male , Female , Middle Aged , Biopsy, Needle , Pleural Effusion , Polysomnography , Sleep
3.
Arq. bras. cardiol ; 94(2): 239-245, fev. 2010. tab, ilus
Article in Portuguese | LILACS | ID: lil-544887

ABSTRACT

FUNDAMENTO: As apneias do sono são doenças frequentes em portadores de insuficiência cardíaca (IC). Estimativas da era pré-betabloqueador (BB) apontam para uma prevalência de 45 por cento de apneias centrais nestes pacientes. OBJETIVO: Avaliar a influência dos BB na prevalência das apneias centrais e sua interferência na qualidade do sono e de vida de portadores de IC. MÉTODOS: 65 pacientes portadores de IC foram submetidos a polissonografia diagnóstica.Os resultados da polissonografia foram avaliados de acordo com o uso ou não de BB. No dia do exame os pacientes responderam ao questionário de Minessota para qualidade de vida com IC. Após 6 e 12 meses da data da polissonografia, houve contato telefônico com todos os pacientes, para a repetição do questionário de Minessota. RESULTADOS: A prevalência de apneia do sono (IAH > 15/h) foi de 46,1 por cento na população total, porém a apneia central foi identificada em apenas 18,4 por cento dos pacientes. O uso de BB, em análise multivariada, foi o único preditor de ocorrência de menor índice de apneia e hipopneia (IAH) central (p=0,002), maior saturação (p=0,02) e menor dessaturação média de oxigênio (p=0,03). Além disso, o uso de BB foi preditor de melhor qualidade de vida após 6 e 12 meses (p=0,002 e 0,001 respectivamente) e de menor número de hospitalizações nestes períodos (p=0,001 e p=0,05 respectivamente). CONCLUSÃO: O uso de BB reduziu a incidência de apneia central na população total, se compararmos com os dados da literatura. Além disto, os BB melhoraram parâmetros da qualidade do sono e de vida de portadores de IC.


BACKGROUND: Sleep apneas are frequent in patients with heart failure (HF). Estimate of the pre-beta blocker age (BB) point out to 45 percent of central apneas in these patients. OBJECTIVE: Assess the influence of BB in central apneas and their interference in the quality of sleep and life of patients with heart failure. METHODS: 65 patients with heart failure underwent diagnostic polysomnography. Polysomnography have been assessed according to the use or not of BB. On the day of examination, the patients answered the Minessota questionnaire for quality of life with HF. After 6 and 12 months from the polysomnography date, all patients were contacted by phone, in order to repeat the Minessota questionnaire. RESULTS: The prevalence of sleep apnea (IAH > 15/h) hit 46.1 percent in the total population, however, central sleep apnea was identified in 18.4 percent of patients. The use of BB, in a multivariate analysis, was the only predictor of a minor index of central apnea and hypopnea (IAH) (p=0.002), greater saturation (p=0.02) and smaller average desaturation of oxygen (p=0.03). Additionally, the use of BB could predict a better quality of life after 6 and 12 months (p=0.002 and 0.001 respectively) and a smaller number admissions in these periods (p=0.001 and p=0.05 respectively). CONCLUSION: The use BB reduced the rate of central sleep apnea in total population, if we compare to literature data. Additionally, the BB improved parameters of quality of sleep and life of patients with heart failure.


FUNDAMENTO: Las apneas del sueño son enfermedades frecuentes en portadores de insuficiencia cardiaca (IC). Una estimación de la era pre betabloqueante (BB) señala hacia una prevalencia del 45 por ciento de apneas centrales en estos pacientes. OBJETIVO: Evaluar la influencia de los BB en la prevalencia de las apneas centrales y su interferencia en la calidad del sueño y de vida de portadores de IC. MÉTODOS: 65 pacientes portadores de IC fueron sometidos a polisonografía diagnóstica. Los resultados de la polisonografía se evaluaron según el empleo o no de BB. El día del examen, los pacientes contestaron el cuestionario de Minnesota para la calidad de vida con IC. Tras 6 y 12 meses de la fecha de la polisonografía, hubo contacto telefónico con todos los pacientes, para la repetición del cuestionario de Minnesota. RESULTADOS: La prevalencia de apnea del sueño (IAH > 15/h) fue de un 46,1 por ciento en la población total, además de la apnea central se identificó en solamente un 18,4 por ciento de los pacientes. El empleo de BB, en análisis multivariado, fue el único predictor de ocurrencia de menor índice de apnea e hipopnea (IAH) central (p=0,002), mayor saturación (p=0,02) y menor desaturación promedio de oxígeno (p=0,03). Además de ello, el empleo de BB fue predictor de mejor calidad de vida tras 6 y 12 meses (p=0,002 y 0,001 respectivamente) y de menor número de hospitalizaciones en estos períodos (p=0,001 y p=0,05 respectivamente). CONCLUSIÓN: El empleo de BB reduzco la incidencia de apnea central en la población total, si lo comparamos con los datos de la literatura. Además de esto, los BB mejoran parámetros de la calidad del sueño y de vida de portadores de IC.


Subject(s)
Female , Humans , Male , Middle Aged , Adrenergic beta-Antagonists/therapeutic use , Heart Failure/drug therapy , Quality of Life , Sleep Apnea, Central/epidemiology , Sleep Apnea, Central/prevention & control , Brazil/epidemiology , Heart Failure/metabolism , Multivariate Analysis , Statistics, Nonparametric , Sleep Apnea, Central/pathology
SELECTION OF CITATIONS
SEARCH DETAIL